📄 OBDV8

OBDV8 – Flashing procedure

Requirements before starting

The following tools/files are required to update/flash a Mobile-Devices device:

  • A pen drive or SD-card reader with an SD card (more than 512 MB, maximum 16 GB)

  • A Mobile-Devices flashing cable (see the pictures below)

  • A 13.8 V power supply for the device and a 5 V supply for the pen drive, using one of the two setups described in "Setup options" below: a PC that powers the pen drive over USB, or the flashing bench with two power supplies

  • An OBD plug (either a cable or the OBD plug from the vehicle)

  • The MDI_PCK* package, obtained only from your Mobile-Devices contact

Here is the flashing cable you will need:


Prepare your pen drive or SD card

The device must detect the USB key within one second. Please use a USB key with a maximum capacity of 16 GB.

  1. Format your pen drive or SD card using FAT32 format.

  2. Extract the content of the "MDI_PCK*" archive on your computer.

  3. Copy the content of the "sd" folder to the root of the pen drive.

Setup options

Option 1: with a PC (1 or 2 devices)

The PC powers the pen drive in 5 V through its USB port, and the device is powered in 13.8 V by a laboratory power supply (or by a vehicle). This avoids needing two power supplies, which is handy when you only have 1 or 2 devices to flash.

Option 2: flashing bench with 2 power supplies (volume)

Connect the device power output cable from the flashing bench to the 13.8 V power supply, and the 5 V cable to the 5 V power supply. This setup is very useful when there is a volume of devices to flash.


Flash the device

  1. The device's battery must be fully charged, otherwise the device will refuse the flashing, resulting in a fast red flashing.

  2. Make sure the device is completely off: it must not be connected to any power supply and its internal battery must be off. The device's LED must be off and not blinking at all.

  3. Connect the pen drive to the device using the flashing cable.

  4. Power the pen drive first: with option 1, power it from the PC USB port; with option 2, turn on the 5 V power supply of the bench.

  5. Turn the device on: turn on the 13.8 V power supply (laboratory power supply or bench), or plug the device in a vehicle.

  6. The flashing process should now begin. Check the LEDs to know the update status (see below).

LED status

Starting

Processing

Critical processing

Done

Failed

Steady red

Slow blinking orange/red (alternating every 0.5 s)

Slow blinking green (0.5 s on, 0.5 s off)

Fast blinking orange/red (alternating every 0.1 s), for at least 30 s

Steady red

During the flashing process

As the firmware is being written, the Orange/Amber light may become irregular or flicker rapidly. Some OS versions may require a modem update, in which case the flashing is done in two passes (ex: OS versions 3.5.24 to 3.5.30) and can take up to about 8 minutes.

Completion sequence

  • Critical processing: the LEDs blink Green.

  • Done: fast blinking Orange/Red. This rapid blinking is the most important part of the sequence: it must last at least 30 seconds to confirm the end of the flashing process.

An example video of the full LED sequence is available here: OBDV8 – LED sequence

After the flashing

Once updated, unplug the pen drive and do a power cycle (unplug and replug the device from power).

If you then browse the pen drive, you will see 2 new files:

  • log_update.txt (log)

  • update_done

If update_done is present, the device has been flashed properly.